Abstract
This paper focus on the analysis and design of a dual 3-phase machine. The possibility to adopt different winding configurations is investigated as a degree of freedom for the designer. The various configurations are analyzed under faulty operating conditions. Both 3-phase and 6-phase operation is considered. Experimental tests for each configuration are reported for both no load and under load operations.